残差放大器(RA)往往主导高精度两步式SAR ADC的噪声与功耗。本工作提出以连续时间(CT)SAR作为第二级,从而省去RA之后的采样操作,避免RA噪声混叠到带内。同时,结合基于跟踪平均的LSB重复技术,宽带RA噪声被降低7dB。该原型ADC采用180nm CMOS工艺实现,在5MS/s采样率下测得约100dB的SNDR。功耗为3.6mW,在100kHz输入频率下获得187.8dB的Schreier FoM。
The residue amplifier (RA) often dominates the noise and power in a high-precision 2-step SAR ADC. In this work, we propose to use the continuous-time (CT) SAR as the second stage, eliminating the sampling operation after RA and thus preventing the RA noise from aliasing into the in-band. Meanwhile, combining with the tracking averaging based LSB repeating technique, the wideband RA noise is reduced by 7dB. The prototype ADC implemented in 180nm CMOS measures ~100dB SNDR with 5MS/s sampling rate. The power consumption is 3.6mW, leading to a Schreier FoM of 187.8dB with 100kHz input frequency.
| 指标 | 数值 | 说明 |
|---|---|---|
| SNDR | 约100dB | 在5MS/s采样率、输入频率最高100kHz下测得 |
| 采样率 | 5MS/s | 原型ADC的工作采样速率 |
| 功耗 | 3.57mW(标称3.6mW) | 其中RA 0.8mW、参考0.98mW、数字1.45mW、其他模拟0.34mW |
| Schreier FoM | 187.8dB | 100kHz输入频率下计算,为目前已发表Nyquist ADC中最佳 |
| 核心面积 | 0.53mm² | 180nm工艺下ADC核心面积 |
| 噪声抑制 | 7dB | 8次LSB重复对RA与比较器噪声的等效平均降噪 |
约100dB SNDR @5MS/s;Schreier FoM 187.8dB(3.6mW)
数字辅助模拟、模拟前端集成
高精度数据采集、精密测量仪器、工业传感