本文提出了一种基于Gm-C滤波器的单环连续时间ΔΣ调制器(CT-DSM),其带宽达到300MHz,是近期已发表的单环DSM中最高的。Gm-C滤波器适合用于宽带CT-DSM,因为它不受OTA增益带宽积的限制,但线性度较差会限制SNDR。为解决Gm-C滤波器线性度差的问题,本文提出两项技术:第一,第一个Gm单元的输入节点采用伪虚地,以减小输入摆幅并改善线性度;第二,提出一种采用局部反馈的线性增强Gm单元。此外,采用6-bit Flash子ADC,并引入累加-复位逻辑以精确校准比较器失调。本工作采用28nm CMOS工艺制造,实测SNDR为67.4dB,Schreier FoM为161.9dB,在带宽超过300MHz的连续时间ADC中处于领先水平。
This paper presents a Gm-C filter based single-loop continuous-time delta sigma modulator (CT-DSM) that achieves 300MHz bandwidth, which is the highest among the recently published single-loop DSMs. Gm-C filters are suitable for wideband CT-DSM as they are not limited by OTA's GWB, but the SNDR is limited due to their poor linearity. To address the poor linearity of Gm-C filters, two techniques are proposed. First, the input node of the first Gm cell utilizes pseudo virtual ground to reduce input swing and improve linearity. Second, a local feedback linearity-enhanced Gm cell is proposed. Moreover, a 6-bit Flash sub-ADC is used. An accumulate-reset logic is adopted to calibrate comparators' offset accurately. This work is fabricated in 28nm CMOS process. The measured SNDR is 67.4dB and the Schreier FoM is 161.9dB, which is a leading FoM for CT-ADCs with bandwidth exceeding 300MHz.
| 指标 | 数值 | 说明 |
|---|---|---|
| 带宽 | 300MHz | 单环CT-DSM的信号带宽,为已发表单环DSM中最高 |
| SNDR | 67.4dB | 芯片实测的信噪失真比 |
| Schreier FoM | 161.9dB | 带宽超过300MHz的CT-ADC中的领先优值 |
| HD3 | -82.2dB | 99MHz、0dBFS输入正弦下的仿真三次谐波失真,较传统Gm-C方案改善14dB |
| 峰值SQNR | >80dB | 行为级模型仿真得到的调制器峰值信噪量化比 |
300MHz 带宽;67.4dB SNDR(Schreier FoM 161.9dB)
噪声整形、自校准与修调、数字辅助模拟
宽带通信系统、软件定义无线电接收机、5G/无线基站