WaytoICT › 香农学术库 › ECOC 2026 › 论文

现场部署的非耦合芯光纤长距离双折射特性表征

Long-Range Birefringence Characterization in a Field-Deployed Uncoupled-Core Fiber
光纤与光缆多芯光纤光纤(空芯/多芯/少模)光传感实验
ECOC 2026University of Padova
偏振OFDR实现千米级四芯光纤双折射分布式测量

基本信息

作者
L. Romero(1), M. Cappelletti(1), C. Antonelli(2,3), A. Mecozzi(2,3), G. Di Sciullo(2,3), T. Hayashi(4), A. Galtarossa(1,3), L. Schenato(1,3), L. Palmieri(1,3)
机构
University of Padova
国家
Japan
会议
ECOC 2026(European Conference on Optical Communication)
电路架构
偏振敏感OFDR系统

摘要

本文给出了现场部署的4芯非耦合芯光纤的分布式双折射测量结果。采用分段补偿的偏振敏感OFDR,我们实现了千米级双折射表征,并在完整重建距离上观察到局部双折射矢量强烈的芯间相关性。在中段进行双向探测进一步印证了测量可靠性。

Abstract

Distributed birefringence measurements are presented for a field-deployed 4-core uncoupled- core fiber. Using polarization-sensitive OFDR with section-wise compensation, we achieve kilometer-scale birefringence characterization and observe strong inter-core correlation of the local birefringence vector over the full reconstructed distance. Bidirectional probing at the midsection corroborates measurement reliability.

关键技术指标

指标数值说明
测量架构偏振敏感 OFDR采用分段补偿实现分布式双折射测量
光纤类型4 芯非耦合芯光纤现场部署
芯数4 芯非耦合芯
表征尺度千米级分布式双折射表征
芯间相关性强芯间相关局部双折射矢量,完整重建距离上观察到
可靠性验证双向探测在中段进行,印证测量可靠性
补偿方式分段补偿用于偏振敏感 OFDR
测量对象分布式双折射局部双折射矢量

性能概述

千米级双折射表征;四芯局部双折射矢量强芯间相关

技术路线

多芯光纤、分布式光纤传感、瑞利散射、现场试验

应用场景

多芯光纤/空分复用系统表征