WaytoICT › 香农学术库 › IEDM 2025 › 论文

面向可穿戴设备人体动脉超声成像的70%带宽PMUT阵列与±5V多电平CMOS发射机首次协同设计

First Codesign of 70%-Bandwidth PMUT Array with ±5V Multi-level CMOS Transmitter for Human Artery Ultrasound Imaging in Wearable Devices
MEMS与生物传感声学谐振器与BAWMEMS谐振器硅基CMOS单片集成实验+仿真
IEDM 2025中国科学院微电子研究所
首次协同设计多尺寸PMUT阵列与±5V多电平CMOS发射机,实现70%带宽与15mm深人体动脉成像。

基本信息

作者
Yucheng Lin1,2,3,†, Tong Jin1,2,†, Hongyang Chen1,2, Tongyu Zhang1,2, Wenchang Zhang1, Zhiqiang Li1,2, Chengjun Huang1,2, Xin Liu1,*, Hang Gao1,*, Ling Li1,2
机构
中国科学院微电子研究所
国家
中国
会议
IEDM 2025(International Electron Devices Meeting)
工艺节点
0.18μm BCD
供电电压
±5V
电路架构
64通道PMUT阵列(1×16通道示意,每通道3×8单元、8种尺寸)、反馈控制高压多电平脉冲发射机、多抽头电阻梯+MUX阈值、比较器闭环调节、片内LNA接收放大

摘要

本文首次提出在0.18μm BCD平台上协同设计的64通道宽带PMUT阵列与多电平CMOS发射机(TxCMOS),在仅±5V驱动电压下于5MHz实现创纪录的70%带宽。我们创新性地将多PMUT通道架构与新型多电平脉冲发生器集成,为可穿戴应用带来高收发效率,其中发射效率达8.4 kPa/V/mm²,自接收灵敏度为1.2 mV/V。与CMOS低噪声放大器(LNA)集成后,接收信号被提升至60mVpp(6倍电压增益)。尤为关键的是,我们首次通过TxCMOS-PMUT实现了人体深部动脉成像,采集到肱动脉(直径5 mm,深度15 mm)的M型超声图像。该系统在上下动脉壁同步跟踪中达到19 µm分辨率,从而可计算与心动周期相关的血压。这一突破使宽带TxCMOS-PMUT成为可穿戴、无创心血管监测与高分辨率深部组织成像的变革性技术。

Abstract

This paper presents the first co-designed 64-channel broadband PMUT array and multi-level CMOS transmitter (TxCMOS) in 0.18μm BCD platform, achieving a record 70% bandwidth at 5MHz with only ±5V drive voltage. Our innovative integration of multi-PMUT channel architecture and novel multi-level pulser enables high transceiving efficiency for wearables, including 8.4 kPa/V/mm² for transmission and 1.2 mV/V for self-reception sensitivity. Integration with a CMOS low-noise amplifier (LNA) boosts received signals to 60mVpp signals (6x voltage gain). Critically, we demonstrate—for the first time—human deep artery imaging via TxCMOS-PMUT, capturing M-mode ultrasound imaging of the brachial artery (5 mm diameter at 15 mm depth). The system achieves 19 µm resolution in simultaneous upper and lower arterial wall tracking, enabling cardiac-cycle-correlated blood pressure calculation. This breakthrough establishes the broadband TxCMOS-PMUT as a transformative technology for wearable, non-invasive cardiovascular monitoring and high-resolution deep-tissue imaging.

关键技术指标

指标数值说明
系统带宽70% @ 5 MHz(±5V驱动)TxCMOS-PMUT系统时域脉冲回波测试达到的-6dB相对带宽
发射效率8.4 kPa/V/mm²在3.27 mm深度由针式水听器测得的单位电压单位面积声压
自接收灵敏度1.2 mV/V @ 6.5 mm以水面为反射体、相邻PMUT通道作接收的脉冲回波灵敏度
接收增益6倍(60 mVpp)集成CMOS LNA后回波信号由11 mVpp提升至60 mVpp
成像分辨率19 µm15 mm深度肱动脉上下壁同步跟踪的最小位移分辨率
单通道PMUT带宽81.7% -6dB2周期10Vpp、5MHz正弦脉冲激励下水中的脉冲回波通道带宽

性能概述

5MHz下70%带宽(±5V驱动);发射效率8.4 kPa/V/mm²

技术路线

低温工艺、图案化与光刻

应用场景

可穿戴医疗超声、心血管无创监测、深部组织高分辨成像

打开交互版 · AI 解读 / 同类对比 / 完整指标在香农学术库中查看(需会员)