提出漂移-扩散蒙特卡洛框架,结合波长相关吸收与实测QE预测FSI SPAD的PDP,全谱误差低于5%。

基本信息

作者
Mathieu Vandwalle1, Anton Greve1, Daniel Gabler1, Mirjam Skadell1, Hannes Schmidt1, Alexander Zimmer1, Vinoothini AP Jeya Kumar2 and Ong Yi Ling2
机构
X-FAB
国家
德国
会议
IEDM 2025(International Electron Devices Meeting)
工艺节点
0.18 μm 模块化 CMOS(X-FAB 标准工艺)
供电电压
2 V 过偏压(excess bias)
工作温度
室温(并在多种温度条件下评估,具体温度值见文中 Table 1)

摘要

本文提出一种增强型漂移-扩散蒙特卡洛框架,用于在紫外-可见-红外(UV–VIS–IR)光谱范围内对正面照式(FSI)单光子雪崩二极管(SPAD)的光子探测概率(PDP)进行预测性建模。该方法将波长相关的吸收建模与实测量子效率(QE)相结合,以估算光学损耗。与传统的基于静态电场的模型不同,本方法利用载流子轨迹(可捕捉耗尽区之外的光生载流子)来计算雪崩击穿概率。本文首次将吸收分布与触发概率分布相结合,在不同器件面积与工艺、不同温度和偏压条件下预测PDP,在整个UV–VIS–NIR光谱范围内相对误差低于5%。此外,对于最小面积器件,在室温与2V过偏压条件下,UV–VIS波段的PDP超过60%。该框架为无需参数拟合的预测性SPAD设计优化提供了稳健且可扩展的仿真工具。

Abstract

An enhanced drift-diffusion Monte Carlo framework is presented for predictive modeling of Photon Detection Probability (PDP) in Front-Side Illuminated (FSI) Single-Photon Avalanche Diodes (SPADs) across the Ultra-Violet-Visible-Infra-Red (UV–VIS–IR) spectrum. This approach combines wavelength-dependent absorption modelling with measured Quantum Efficiency (QE) to estimate optical losses. Carrier trajectories capturing photo-generated carriers outside depletion region are used to compute avalanche breakdown probabilities, in contrast to conventional static electric-field-based models. For the first time, absorption and triggering profiles are integrated to predict PDP across various device areas and processes at various temperatures and voltages achieving relative errors below 5% across the entire UV–VIS–NIR spectrum. Beside this, PDP values exceeding 60% in the UV–VIS range were achieved for smallest area at room temperature and 2V excess bias. This framework provides a robust and scalable simulation tool for predictive SPAD design optimization without parameter fitting.

关键技术指标

指标数值说明
PDP预测相对误差<5%在整个UV–VIS–NIR光谱范围内,跨不同面积、工艺、温度和偏压的预测相对误差均低于5%
光子探测概率(PDP)>60%最小面积器件在室温、2V过偏压下的UV–VIS波段PDP超过60%
仿真加速比200×借助Numba编译,运行1000步仿真时获得约200倍加速
仿真运行时间1000步:274 s(8 jobs)/ 49 s(40 jobs)运行时间随步数线性增长,并与核数成反比
蒙特卡洛仿真配置100×100 网格、每点100次试验、10^7步×1 ps最多100个载流子,等效模拟时长可达10 μs

性能概述

PDP相对误差 <5%(UV–VIS–NIR全谱);UV–VIS波段PDP >60%(最小面积、室温、2V过偏压)

技术路线

光电探测器、直接检测(IM/DD)

应用场景

LiDAR与ToF测距、荧光寿命成像(FLIM)、医学与生命科学检测