本工作展示了一种单电子灵敏的SiC探测器,采用等电位保护环与低漏电工艺技术,在200 V偏置下实现0.05 pA暗电流并具备200°C下的稳定性;对0.78 pA至410 nA的宽束流范围呈线性响应,相对暗电流的对比度超过10⁴,电子探测效率达95%。该探测器首次实现了基于单电子探测的成分与空间信息时间域分析,其中时间数字转换器的时间抖动为92.5 ps,探测系统时间分辨率为6.62 ns,从而支持直接的单电子能量谱分析。该探测器对1.86 GeV重离子和10⁷ A/cm²的30 keV电子束辐照表现出优异的耐受性,进一步证明这种单电子探测器不仅能把电子显微从统计平均提升到单量子事件研究,还能在恶劣环境下工作。
This work demonstrates a single-electron-sensitive SiC detector featuring an iso-potential guard ring and low-leakage processing techniques, achieving 0.05 pA dark current at the bias of 200 V with 200°C stability, linear response covering a wide beam current range from 0.78 pA to 410 nA with a contrast ratio exceeding 10⁴ over dark current, and a 95% electron detection efficiency. The detector demonstrates for the first time single-electron-detection-based temporal analysis on compositional and spatial information, where 92.5 ps time jitter in the time-to-digital converter and 6.62 ns time resolution in the detection system has been achieved, facilitating direct single electron energy spectroscopy. The detector superior ruggedness against 1.86 GeV heavy ions and 10⁷ A/cm² 30 keV electron beam irradiation further verifies that, this single electron detector could elevate the electron microscopy from statistical averaging not only to single-quantum-event studies, but also to operations in harsh environment.
| 指标 | 数值 | 说明 |
|---|---|---|
| 暗电流 | 0.05 pA | 200 V偏置下暗电流,且在200°C高温下保持稳定 |
| 电子探测效率 | 95% | 按4H-SiC平均电子-空穴对产生能7.8 eV计算,并计入顶部300 nm p层能量沉积 |
| 响应动态范围/对比度 | >10⁴(0.78 pA–410 nA) | 输出电流与电子束流保持良好线性,相对暗电流对比度超过10⁴ |
| 时间抖动(TDC) | 92.5 ps | 时间数字转换器测得的时间抖动 |
| 系统时间分辨率 | 6.62 ns | 探测系统整体时间分辨率,支撑单电子到达时间分析 |
| 空间分辨率 | ~220 nm(灰度对比10%-90%) | 重构图像中可分辨亚微米结构,10%-20%灰度对比下为34 nm |
暗电流0.05 pA(200 V偏置、200°C稳定);电子探测效率95%
光电探测器、热稳定性、原位表征
电子显微镜成像与成分分析、集成电路失效分析与工艺检测、辐照恶劣环境探测
打开交互版 · AI 解读 / 同类对比 / 完整指标在香农学术库中查看(需会员)