本工作提出了一种在柔性衬底上单片集成传感电极阵列(SEA)、模拟前端(AFE)与人工神经网络(ANN)的神经形态生物信号处理系统。该系统采用以铟镓锌氧化物为半导体的双栅(DG)薄膜晶体管(TFT),通过温度梯度工艺制备,以抑制多层硅烷基沉积过程中的氢释放。AFE与ANN堆叠在SEA下方,形成3D架构。双栅TFT动态补偿方法使AFE在工艺波动下仍保持高性能,在仅1.5 mm²的紧凑面积内实现了62.3 dB增益、1.1 kHz带宽和74.5 dB共模抑制比。ANN利用双栅TFT实现存内计算,一个栅用于数据存储、另一个栅用于权重存储,在四类心搏信号上取得96%的分类准确率。
This work presents a neuromorphic bio-signal processing system that monolithically integrates a sensing electrode array (SEA), analog front-end (AFE), and artificial neural network (ANN) on a flexible substrate. The system utilizes dual-gate (DG) thin-film transistors (TFTs) with indium gallium zinc oxide as the semiconductor, fabricated via a temperature gradient process to suppress hydrogen release during multi-layer silane-based deposition. The AFE and ANN are stacked beneath the SEA, forming 3D architecture. A DG-TFT dynamic compensation method ensures the AFE maintains high performance under process variations, achieving a gain of 62.3 dB, a 1.1 kHz bandwidth, and a 74.5 dB common-mode rejection ratio within a compact 1.5 mm² footprint. The ANN uses DG-TFTs for in-memory computing, with one gate for data storage and the other for weight storage, achieving 96% classification accuracy across four heartbeat signal classes.
| 指标 | 数值 | 说明 |
|---|---|---|
| 增益 | 62.3 dB | AFE两级差分放大器在动态补偿下的闭环增益 |
| 共模抑制比 | 74.5 dB | AFE在1.5 mm²面积内实现的CMRR |
| 带宽 | 1.1 kHz | 满足心电/肌电等生物信号的采集带宽 |
| 分类准确率 | 96% | 双栅TFT存内计算ANN对四类心搏信号的识别精度 |
| 迁移率 | 9.3 cm²/V·s | W/L=5/5 μm的TGSA TFT在20颗器件上的平均电子迁移率(7.1–10.2 cm²/V·s) |
| 面积 | 1.5 mm² | AFE所占芯片面积 |
增益 62.3 dB;四类心电信号分类准确率 96%
单片3D集成、存内计算、神经形态、机器学习
可穿戴生物信号监测、柔性电子、神经形态计算
打开交互版 · AI 解读 / 同类对比 / 完整指标在香农学术库中查看(需会员)