WaytoICT › 香农学术库 › OFC 2025 › 论文

城市管道网络部署的20km反谐振空芯光纤上实时128Tb/s同频同时全双工传输现场试验

Field Trial of Real-time 128Tb/s Co-frequency Co-time Full-duplex Transmission over Deployed 20km AR-HCFs in Urban Duct Network
光传输系统现场试验与现网验证光纤(空芯/多芯/少模)相干通信实验
OFC 2025中国移动研究院
首次在深圳-东莞城市管道实装20km反谐振空芯光纤上实现实时128Tb/s同频同时全双工传输。

基本信息

作者
Dawei Ge1, Siyuan Liu1,6, Peng Li2, Qiang Guo3, Yifan Xiong4, Mingqing Zuo1, Dong Wang1, Shoufei Gao4,5, Dechao Zhang1,*, Da Liu7, Yingying Wang4,5, Lei Zhang2, Wei Ding4,5, Jie Luo2, Hongqiang Zou7, Han Li1, Zhangyuan Chen6, and Xiaodong Duan1
机构
中国移动研究院
国家
中国
会议
OFC 2025(Optical Fiber Communication Conference)

摘要

我们报道了首次在中国复杂城市管道网络中部署的20km反谐振空芯光纤(AR-HCF)上开展的实时128Tb/s同频同时全双工传输,利用AR-HCF极低的分布式瑞利背散射特性实现双向同频同时传输。

Abstract

We report the first real-time 128Tb/s co-frequency co-time full-duplex transmission over the first deployed 20km AR-HCFs in complex urban duct network in China by leveraging extremely low distributed Rayleigh backscattering of AR-HCF. © 2025 The Author(s)

关键技术指标

指标数值说明
双向净传输容量128Tb/s2方向×120λ×800Gb/s,C6T+L6T波段商用800G光模块
实装链路长度19.66km(NANF-5)/20.33km(TDNANF-4)深圳龙岗—东莞凤岗城市管道部署,两芯串接构成20km单跨
最低链路损耗0.599dB/km部署后实测NANF-5链路损耗,TDNANF-4为0.785dB/km
色散系数2~5 ps/nm/kmC6T+L6T范围内实测,远低于G.652.D
环形器背向反射<-50dB用3端口光环形器替代50:50耦合器实现双向合波

性能概述

双向净速率128Tb/s(2方向×120λ×800Gb/s);实装20km空芯光纤链路最低损耗0.599dB/km

技术路线

空芯光纤、波分复用、相干检测、瑞利散射、现场试验

应用场景

数据中心互联、金融高频交易低时延链路、城域光网络

打开交互版 · AI 解读 / 同类对比 / 完整指标在香农学术库中查看(需会员)