WaytoICT › 香农学术库 › IEDM 2025 › 论文

具有稳健非破坏性漏极击穿的增强型 p-GaN 栅穿通 HEMT

E-Mode p-GaN Gate Punch-Through HEMT with Robust Non-Destructive Drain Breakdown
功率与宽禁带器件GaN HEMTGaN HEMTGaN-on-Si实验+仿真
IEDM 2025北京大学
提出p-GaN穿通栅增强型GaN HEMT,实现可重复非破坏性击穿,874 V阻断、超100次击穿无退化。

基本信息

作者
Jingjing Yu1#, Junjie Yang1#, Yunhong Lao1, Sihang Liu1, Han Yang2, Xuelin Yang2, Maojun Wang1, Kevin J. Chen3, Bo Shen2* and Jin Wei1*
机构
北京大学
国家
中国
会议
IEDM 2025(International Electron Devices Meeting)
供电电压
VGS = 3.5 V(导通测试);关断态 VDS 偏置至 874 V
工作温度
25–125 ℃
电路架构
多指(multi-finger)PT-HEMT 器件,p-GaN 岛阵列作控制栅(岛宽 10 μm、间距 60 μm)

摘要

本工作提出了一种增强型 p-GaN 栅穿通 HEMT(PT-HEMT),可实现重复的非破坏性击穿,解决了传统 GaN HEMT 长期存在的缺乏雪崩鲁棒性问题。该 PT-HEMT 沿器件宽度方向采用 p-GaN 岛阵列作为控制栅,并采用从栅极向漏极延伸的减薄 p-GaN 层作为穿通栅(PT-gate)。在关断态下,高漏偏压使 PT-gate 完全耗尽,其下方的 2DEG 沟道被穿通,从而产生非破坏性击穿。因此,漏电压被钳位在低于破坏性击穿的穿通电压,以耗散瞬态过压尖峰。PT-gate 耗尽电压与穿通击穿电压数值吻合,验证了该机制。面向 650 V 等级,LGD = 12 μm 的 PT-HEMT 实现了 874 V 的非破坏性击穿电压。穿通击穿表现出正温度系数。在电流驱动击穿测试中,PT-HEMT 经受住 100 次以上重复击穿循环,阈值电压、RON 和动态 RON 的退化可忽略。PT-HEMT 天生具备处理高功率开关应用中瞬态过压尖峰的能力。

Abstract

This work presents an E-mode p-GaN gate punch-through HEMT (PT-HEMT) which could achieve repetitive non-destructive breakdown, addressing the long-standing issue in conventional GaN HEMTs—the lack of avalanche robustness. The PT-HEMT features an array of p-GaN islands along the width of the device as control gate, and a thinned p-GaN layer extending from gate toward drain as punch-through gate (PT-gate). In the OFF-state, high drain bias induces full depletion of the PT-gate, so the underlying 2DEG channel is punched through, resulting in a non-destructive breakdown. Thus, drain voltage is clamped at punch-through voltage lower than that for destructive breakdown to dissipate transient overvoltage spikes. This mechanism is validated by the matched values between PT-gate depletion voltage and punch-through breakdown voltage. For 650-V rating, PT-HEMT with LGD = 12 μm achieves a non-destructive breakdown voltage of 874 V. The punch-through breakdown exhibits a positive temperature coefficient. Under current-driven breakdown tests, the PT-HEMT survives more than 100 repetitive breakdown cycles, with negligible degradation of threshold voltage, RON, and dynamic RON. The PT-HEMTs are empowered with an inherent capability to handle transient overvoltage spikes in high-power switching applications.

关键技术指标

指标数值说明
非破坏性击穿电压874 VLGD = 12 μm 的 PT-HEMT,对应 650 V 电压等级,低于同尺寸常规 HEMT 的 1176 V 破坏
比导通电阻 RON11.1 Ω·mmVGS = 3.5 V 下测得,与常规 p-GaN 栅 HEMT 的 11.3 Ω·mm 相当
阈值电压 VTH1 V定义为 ID = 10 μA/mm,PT-HEMT 与常规器件一致
重复击穿次数>100 次电流驱动击穿测试下阈值电压、RON 与动态 RON 退化可忽略
击穿电压温度系数574 V→664 V(25 ℃→125 ℃)LGD = 7 μm 时穿通击穿电压随温度升高而上升,呈正温度系数
2DEG 方阻450–460 Ω/sqTLM 测得:SiO2 钝化区 460 Ω/sq,减薄 p-GaN 覆盖区 450 Ω/sq

性能概述

非破坏性击穿电压 874 V(LGD = 12 μm);比导通电阻 RON = 11.1 Ω·mm

技术路线

外延生长、图案化与光刻、热稳定性、失效分析

应用场景

高功率开关电源、工业电源、消费电子快充

打开交互版 · AI 解读 / 同类对比 / 完整指标在香农学术库中查看(需会员)