随着DRAM微缩向采用硅基选择晶体管的密集三维架构推进,浮体效应(FBE)因瞬态泄漏及相关的数据保持风险而成为关键可靠性问题。本工作提出了首次在纳米片GAA 3D DRAM访问晶体管中实验提取浮体感应双极电流(FBC)的方法,利用晶体管阵列来访问单器件测量无法达到的低IOFF区间。研究了两组按高、低准静态(QS)泄漏划分的器件群体,采用能够分离瞬态寄生BJT贡献的测量协议。分析了FBC幅度随预充电时间和泄漏的变化关系,揭示其对体充电动力学的强烈依赖。结合TCAD支持,向目标IOFF指标的外推表明浮体效应预计可被有效抑制。这些发现为硅基3D DRAM架构提供了关键可靠性指导。
As DRAM scaling advances toward dense 3D architectures with Si-based select transistors, floating body effects (FBE) emerge as a critical reliability concern due to transient leakage and associated data retention risks. This work presents the methodology for the first experimental extraction of floating-body-induced bipolar current (FBC) in nanosheet GAA 3D DRAM access transistors, leveraging transistor arrays to access low IOFF regimes inaccessible to single-device measurements. Two device populations, defined by high and low quasi-static (QS) leakage, are studied using a measurement protocol that isolates the transient parasitic BJT contribution. FBC amplitude is analyzed as a function of pre-charge time and leakage, revealing strong dependence on body charging dynamics. Extrapolation toward target IOFF specifications, supported by TCAD, shows that floating body effects are expected to be effectively suppressed. These findings provide key reliability guidance for Si-based 3D DRAM architectures.
| 指标 | 数值 | 说明 |
|---|---|---|
| 开态电流 ION | 19.8 µA @ VDS=1 V | 单个GAA纳米片器件的开态电流 |
| 亚阈值摆幅 SS | 80 mV/dec | 单器件关态开关特性 |
| 阈值电压 VTH | 0.38 V | 在1 nA·WEFF/LG判据下提取 |
| 阵列规模 | 390,000 个并联晶体管 | 电流放大以支持sub-pA/device的IOFF提取 |
| 纳米片厚度/栅长 | 约12 nm / 约95 nm | TEM截面确认的器件几何尺寸 |
| 预充电时间范围 | 1 ms – 100 ms | FBC峰值随预充电时间增大并饱和 |
单器件 ION = 19.8 µA @ VDS=1 V;SS = 80 mV/dec
GAA、垂直堆叠
高密度3D DRAM存储、先进存储阵列可靠性评估
打开交互版 · AI 解读 / 同类对比 / 完整指标在香农学术库中查看(需会员)