摘要

我们报道了首次成功利用射频共溅射在n⁺-Si衬底上沉积NbSeVOx敏感膜阵列。经600 °C退火的薄膜表现出优异性能,包括高pH灵敏度(63.6 mV/pH)、超低迟滞(1.1 mV)和极小漂移(0.13 mV/h)。在生物传感方面,薄膜表面用APTE功能化以引入氨基,从而能够固定cTnI、BNP和NT-proBNP抗体。所得EGFET生物传感器对cTnI(5.76 mV/pCcTnI)、BNP(5.01 mV/pCBNP)和NT-proBNP(6.88 mV/pCNT-proBNP)在宽动态范围(10⁻⁶–10⁵ pg/mL)内表现出强灵敏度。测得的血清浓度与ELISA结果高度吻合,证实了临床准确性。这种基于NbSeVOx的EGFET为蛋白质检测提供了一种无创、高灵敏且稳定的平台,可检测低至ag/mL量级,动态范围跨越12个数量级以上。

Abstract

We report the first successful RF co-sputtered deposition of NbSeVOx sensing film arrays on n+-Si substrates. The film annealed at 600 °C exhibited excellent performance, including high pH sensitivity (63.6 mV/pH), ultra-low hysteresis (1.1 mV), and minimal drift (0.13 mV/h). For biosensing, the film surface was functionalized with APTE to introduce amino groups, enabling the immobilization of cTnI, BNP, and NT-proBNP antibodies. The resulting EGFET biosensor showed strong sensitivity to cTnI (5.76 mV/pCcTnI), BNP (5.01 mV/pCBNP), and NT-proBNP (6.88 mV/pCNT-proBNP) over a wide dynamic range (10-6–105 pg/mL). The measured serum concentrations closely matched ELISA results, confirming clinical accuracy. This NbSeVOx-based EGFET provides a noninvasive, highly sensitive, and stable platform for protein detection down to the ag/mL level, with a dynamic range spanning more than 12 orders of magnitude.

关键技术指标

指标数值说明
pH灵敏度63.6 mV/pH600 °C退火样品在pH 2–12范围内的灵敏度,为三种退火温度中最高
迟滞电压1.1 mV600 °C退火传感器迟滞最小,归因于氧空位减少
漂移率0.13 mV/h600 °C退火样品稳定性最佳,700 °C样品漂移高达1.45 mV/h
cTnI灵敏度5.76 mV/pC对心肌肌钙蛋白I的线性响应灵敏度,线性度R²=99.96%
NT-proBNP灵敏度6.88 mV/pC对N端脑钠肽前体的响应灵敏度,线性度R²=99.83%
检测下限(LOD)5×10⁻⁶ pg/mL动态范围10⁻⁵–10⁶ pg/mL,跨越12个数量级

性能概述

pH灵敏度63.6 mV/pH;cTnI检测灵敏度5.76 mV/pC、检测下限5×10⁻⁶ pg/mL

技术路线

图案化与光刻、热稳定性

应用场景

心血管疾病标志物检测、即时诊断(POC)、无创健康监测