800G Optical Module MSA: Technical Analysis of 8x100G in SR Scenarios

Posted on 2020-09-29 by

Background of 800G Optical Module Technology

For 800G optical module interface technology, there are two main organizations: the 800G Pluggable MSA working group and the QSFP-DD800 MSA. Based on the 800G technology white paper published by the 800G Pluggable MSA working group, its main application scenarios are the 8x100G solution for SR short-reach scenarios around 100 meters in data centers, the 4x200G solution for FR scenarios around 2 km, and possible 800G solutions for DR scenarios around 500 m. Today we focus on the 8x100G technology in SR scenarios.

800G Optical Module MSA: Technical Analysis of 8x100G in SR Scenarios

Current data center architectures can mainly be divided into two types. One is the three-tier hyperscale data center architecture, with a certain oversubscription ratio between layers, such as 3:1. Above the Spine layer, coherent optical interconnect solutions such as ZR are used to connect with other data centers, as shown below. This structure is a traffic-converging network, usually depending on the balance between service requirements and CapEx optimization.

800G Optical Module MSA: Technical Analysis of 8x100G in SR Scenarios

The other is a two-tier data center network architecture based on AI clusters, as shown below. It has fewer layers than the first architecture, with no oversubscription between layers, which means larger data traffic. In this structure, each Leaf connects directly to server interfaces, but the traffic exchange is much smaller. At the same time, its deployment speed is faster than the first architecture, with almost no traffic convergence.

800G Optical Module MSA: Technical Analysis of 8x100G in SR Scenarios

So in which scenarios do the above architectures require 800G interfaces? According to the white paper: in the first typical architecture, if the rate between Server and TOR reaches 200G, then 800G (4x200G) is needed further up. For the second data center architecture, when the traffic between Server and Leaf reaches 2x200G, the Leaf layer needs 800G bandwidth interfaces upward.

In addition, in the above two architectures, the distance from service to Leaf is usually 4 m within a rack / 20 m across racks, from TOR to Leaf is about 60-100 m, from Leaf to Spine is typically 500 m to 2 km, and finally from Spine to DCI and interconnects between them is around 80-120 km. As mentioned at the beginning, one goal of the MSA is to address 800G interface technology in SR scenarios, namely the SR 8x100G technology covering around 100 m, and the other is to address the FR and DR scenarios of 500 m to 2 km.

Technical Analysis of 8x100G in SR Scenarios

For the MSA and related vendors, their goal is to develop low-cost 8x100G optical modules, and this low-cost approach is to define a transmitter technology that reduces cost linearly through high integration. Given the trend of ever-increasing switch ports and decreasing server count per rack, low-cost 800G can also be used to support serial 100G server connections. Traditional interconnects between domestic data centers rely on VCSEL multimode transmission supporting 30-50 m, while the MSA side is based on single-mode fiber interconnect using 100G PAM4 technology. Instead of VCSEL-based multimode solutions, it adopts parallel single-mode fiber (SMF) transmission using PSM8 with PAM4 modulation format (with built-in DSP chip) to meet the 800G SR scenario requirements, as shown below.

800G Optical Module MSA: Technical Analysis of 8x100G in SR Scenarios

To ensure the low-cost and low-power advantages of 800G-SR8 over single-mode SMF, the MSA has established three principles for defining a reasonable PMD layer standard for 800G-SR8:

  • Multiple transmitter technology options, such as DML, EML, and silicon photonics (SiPh);
  • Full utilization of device capabilities to achieve the target link performance;
  • Relax PMD layer parameters as much as possible as long as reliable link performance is met.

The power budget of the SMF-based 800G-SR8 solution is similar to that defined in IEEE 400G-SR8, with the difference being the added insertion loss of the PSM8 connector. That is, the SR8 power budget can be guaranteed based on current 400GE DSP ASICs and mature optical/electronic components. In addition, the biggest challenge of the 800G-SR8 PMD lies in finding the right transmitter optical modulation amplitude (OMA), extinction ratio (ER), transmitter eye diagram closure penalty (TDECQ), and receiver sensitivity. The MSA working group compares the BER performance of different transmitters to determine these parameters, as shown below.

800G Optical Module MSA: Technical Analysis of 8x100G in SR Scenarios

(a) BER vs. OMA results of EML transmitters tested with commercial 400G DSP chips; (b) BER vs. OMA results of SiPh transmitters tested with commercial 400G DSP chips; (c) BER vs. OMA results of DML transmitters tested with commercial 400G DSP chips.

The above comparisons are all based on test results on 400G DSP chips. Schemes a and b have been widely discussed. In scheme c, the BER performance of DML shows that under these conditions the OMA sensitivity is comparable to that of EML and SiPh. Considering the lower transmit power of SiPh and the sufficiently high sensitivity of all three schemes, the minimum OMA requirement in 800G-SR8 can be appropriately relaxed. Meanwhile, considering the relatively low sensitivity requirement in SR scenarios and the power constraints of 800G modules, the MSA also recommends using low-complexity DSP modes. Another parameter is the extinction ratio (ER), which is also directly related to power consumption; generally, as long as the ER does not affect link reliability, the smaller the ER the better.

Based on the above analysis, in the 800G-SR solution, a low-cost and low-power solution based on single-mode SMF is also feasible. Next time we will look at the 4x200G solution.

The above article is a partial interpretation of the MSA 800G optical module technology white paper.


800G Optical Module MSA: Technical Analysis of 8x100G in SR Scenarios


Related Reading

  • 800G OSFP Optical Module Evolution Roadmap
  • Ciena: 800G and Higher-Rate Coherent Pluggable Optical Modules
  • Key Requirements of 800G MSA Pluggable Modules

Enjoy this article?

Subscribe to get new optical communication insights delivered to your inbox. Free, unsubscribe anytime.

Category: Technology

Leave a Reply

You must be logged in to post a comment.

订阅更新

订阅后,新文章发布时第一时间收到邮件通知

李东霏
光互连技术研究者

香农信息技术研究院,专注光模块、CPO、硅光与 AI 光互连的技术解读。

行业报告

光芯片·光器件·光模块 2026 报告汇编(含 OFC 2026)

光芯片 · 光器件 · 光模块
2026 报告汇编(含 OFC 2026)

¥1,900

上/下两册,收录 OFC 2026 一线报告
添加微信 WaytoICT 订购

广告

📢 广告位招商:面向全球光通信客户 侧边栏广告位 Email:Dongfei.li@shannoninstitute.cn

最新文档

  • 互连拐点:11 页解析机架内到多机架 Scale-Up 的 XPO/CPX/OCI 蓝图(OCP 2026 全球峰会)
  • AI 时代的相干光技术:17 页解析 Scale-Across、液冷 XPO 与全谱转发器(OCP 2026 全球峰会)
  • XPO 高密度光互连的系统级评估:20 页解析 212G SerDes 平台与 FRO/LRO/LPO 实测(OCP 2026 全球峰会)
  • CPO 与 OCI 标准及未来技术:17 页 Broadcom 精简版演讲提纲(OCP 2026 全球峰会)
  • VCSEL 高密度互连:7 页解析 50G NRZ「慢而宽」阵列与光 PCIe 演示(OCP 2026 全球峰会)

最新评论

暂无评论,欢迎登录后发表第一条评论。

最近访客

👥 今日访客 -
加载中…
© 2026 WaytoICT | 蜀ICP备2020035321号-2 | 隐私政策 | 免责声明
Wechat Pay
Alipay
请使用 支付宝 或 微信 扫码支付