Skip to content

WaytoICT

Optical & AI Networking Explained

中文English
Log InSign Up
Menu
Technology Optical comms · silicon photonics · CPO → Market Insights Financials · trends · industry → In-Depth Analysis Optical chips, devices & modules → Video Understand a topic in minutes → Document Insights Read PDFs · AI summaries · downloads → Shannon Library ECOC paper database · AI Q&A →
Menu

The Challenges of 800G and 1.6T Networks!

Posted on 2024-02-01 by Dongfei Li

We know that increasing the baud rate speeds up the transmission of symbols in the channel, but may lead to greater signal attenuation. Adding pulse amplitude modulation (PAM) schemes allows each symbol to send more bits, but with a lower error margin and stricter thresholds.

The international organizations IEEE and OIF have both begun defining 800G and 1.6T on 224 Gb/s lanes. The following are several challenges and potential solutions for realizing 800G and 1.6T (based on 224 Gb/s lane rates).

  • Switch Silicon SerDes

Faster network switch chips are crucial to improving lane speeds. High-speed application-specific integrated circuits (ASICs) enable low-latency switching between components in server racks and data centers. From 2010 to 2022, through multiple improvements in complementary metal-oxide-semiconductor (CMOS) process technology, switch silicon bandwidth increased from 640 Gb/s to 51.2 Tb/s.

SerDes (serializer/deserializer) speed and the number of SerDes (I/O pins) define the chip’s bandwidth. For example, a chip with 51.2 Tb/s bandwidth has 512 10 Gb/s SerDes, enough to support 128 ports of 400G Ethernet capacity, each port consisting of four 100 Gb/s lanes. The next generation of switch silicon will again double the bandwidth, and a 102.4T switch will have 512 200 Gb/s SerDes lanes. These silicon switches will support 800G and 1.6T through 224 Gb/s lanes.

  • Pulse Amplitude Modulation

Increasing the symbol rate (baud rate) causes signal attenuation because data moves faster in the channel. Maintaining signal integrity for high-speed digital communication becomes more complex, so standards organizations have adopted higher modulation schemes to increase the number of bits per symbol. For example, 400G Ethernet uses four-level pulse amplitude modulation (PAM4) SerDes, raising the data rate from 50 Gb/s to 100 Gb/s at the same symbol rate of 50 GBd. With this change, 400G networks can begin using four 100 Gb/s lanes instead of eight 50 Gb/s lanes.

Pulse amplitude modulation requires trade-offs. Sending more bits per cycle reduces the noise margin of each symbol. With non-return-to-zero (NRZ) signaling, the voltage threshold range for distinguishing a zero bit from a one bit is higher. As the number of bits per symbol increases, the thresholds become smaller and smaller, and noise immunity also declines. Under 50 GBd NRZ conditions, the noise level does not close the eye diagram, meaning the receiver can clearly distinguish bit levels, but for a receiver trying to interpret 50 GBd PAM4 symbols, this can be troublesome.

The Challenges of 800G and 1.6T Networks!
Add image caption, no more than 140 characters (optional)

Figure: Eye diagram comparison of NRZ and PAM4

The eye height of a PAM4 signal is smaller, so it has a smaller design margin in terms of noise and jitter. At present, the industry may retain the generality of PAM4 and instead study other methods to maintain data integrity at high speeds. But future standards may adopt higher modulation schemes (PAM6 or PAM8). What Is the Investment Value of 800G Optical Transceivers and Optical Chips?

  • How Does Forward Error Correction Reduce the Bit Error Rate?

In most high-speed data standards, finely tuned equalizers in the transmitter and receiver ensure that the signal transmitted through the channel can be interpreted at the other end, thereby compensating for signal attenuation in the channel. However, as rates further break through physical limits, more complex methods are needed.

One such solution is forward error correction.

Forward error correction refers to transmitting redundant data to help the receiver piece together signals that may have corrupted bits. Forward error correction algorithms usually recover data frames well when random errors occur, but are less effective for burst errors that lose entire data frames.

Losing entire data frames makes it harder for the receiver to reconstruct the signal. For example, a 224 Gb/s transceiver needs a more powerful FEC algorithm to successfully transmit and receive data. Each FEC architecture has trade-offs and advantages in coding gain, overhead, latency, and energy efficiency.

The Challenges of 800G and 1.6T Networks!
Add image caption, no more than 140 characters (optional)

Figure: Types of FEC architectures

The Challenges of 800G and 1.6T Networks!
Add image caption, no more than 140 characters (optional)

Figure: Trade-offs of different FEC types

Although FEC helps mitigate the impact of random errors between the transmitter and receiver, burst errors still cause problems. In 224 Gb/s systems, more complex FEC algorithms must be adopted to minimize burst errors. Test and measurement developers are developing FEC-aware receiver test solutions to identify when frame loss occurs and help debug.

800G Optical Transceivers Expected to Remain Bullish, Domestic Optical Transceiver and Optical Chip Manufacturers May Continue to Benefit

  • How Do Optical Transceivers Affect Energy Efficiency?

The most severe challenge facing data centers may be power consumption, that is, electricity consumption. Data centers account for about 1% of total global power generation. Data center operators hope to increase processing capacity without a corresponding increase in power consumption, and optical transceivers are one of the key components for improving energy efficiency.

As far as we know, the power consumption of each generation of optical transceivers is increasing. For example, the power consumption of a 100G pluggable module (QSFP28) is less than 5W, but the power consumption of a 400G QSFP-DD module is as high as 14W.

Of course, as optical transceiver designs mature, they will become more energy-efficient. Taking the 800G QSFP-DD module as an example, its power consumption at first appearance was 17W; as the technology matures, the power consumption should drop to 10W. Generally speaking, the power consumption per bit is declining. However, since each data center has an average of 50,000 optical transceivers, the rising average power consumption of modules is still a problem.

The Challenges of 800G and 1.6T Networks!
Add image caption, no more than 140 characters (optional)

Figure: Power consumption across generations of optical transceivers (source: Eoptolink)

To improve energy efficiency, R&D personnel are studying new packaging schemes. CPO co-packaged optics has the potential to achieve the lowest power consumption. Co-packaged optics moves the optical module to the ASIC, eliminating the optical retimer and performing optical-electrical conversion within the package. The cost here is that power dissipation is concentrated within the ASIC package, which may require new cooling solutions.

The Challenges of 800G and 1.6T Networks!
Add image caption, no more than 140 characters (optional)

Figure: Pluggable module

The Challenges of 800G and 1.6T Networks!
Add image caption, no more than 140 characters (optional)

Figure: Co-packaged module

Cooling is another major power-consuming factor in data centers. Co-packaged optics is still under development, so the industry may continue to use pluggable optics in 800G systems. Later versions of the 800G or 1.6T standards may use co-packaged optics.

  • What Is the Timeline for 800G and 1.6T Networks?

Although the future cannot be predicted accurately, we can offer some views based on the current state of network R&D. In 2022, OIF’s 112 Gb/s standard and IEEE’s 802.3ck (400G) standard were finally released. These standards will lay the foundation for defining 800G on 112 Gb/s lanes.

Within the next two years, IEEE and OIF will finalize physical layer standards and release more news about co-packaged optics, 1.6T transceivers, and 224 Gb/s SerDes switch chips, which will lay the foundation for the final validation of 800G and 1.6T using 224 Gb/s lanes.

Currently, 400G is undergoing large-scale deployment. Operators will upgrade hyperscale data centers to support the current wave of demand. By 2025, we may see 448 Gb/s SerDes chips (using 102.4T ASICs) appear on the market. By then, we may be discussing 3.2T network requirements.


Related Reading

  • Analysis of 8x100G Technology in the SR Scenario of MSA’s 800G Optical Transceiver
  • 600G or 800G?
  • Is the Single-Wavelength 800G Scheme Commercially Viable?

Enjoy this article?

Subscribe to get new optical communication insights delivered to your inbox. Free, unsubscribe anytime.

Category: Technology

Leave a Reply

You must be logged in to post a comment.

Subscribe

Get notified by email when new posts are published.

Dongfei Li
Optical Interconnect Researcher

Shannon Information Technology Institute — focused on optical modules, CPO, silicon photonics, and AI optical interconnect.。

Industry Reports

Optical Chips, Devices & Modules 2026 Report Collection (incl. OFC 2026)

Optical Chips · Devices · Modules
2026 Report Collection (incl. OFC 2026)

¥1,900

Two volumes covering first-hand OFC 2026 reports
Add WeChat WaytoICT to order

广告

📢
Ad space available: for global optical communication clients
Sidebar Ad
Email:Dongfei.li@shannoninstitute.cn

Latest Documents

  • Rubin Ultra 的 CPO 市场机会有多大
  • Coherent 2026 年欧洲光通信大会(ECOC 2026)
  • 互连拐点:11 页解析机架内到多机架 Scale-Up 的 XPO/CPX/OCI 蓝图(OCP 2026 全球峰会)
  • AI 时代的相干光技术:17 页解析 Scale-Across、液冷 XPO 与全谱转发器(OCP 2026 全球峰会)
  • XPO 高密度光互连的系统级评估:20 页解析 212G SerDes 平台与 FRO/LRO/LPO 实测(OCP 2026 全球峰会)

Recent Comments

No comments yet. Log in to post the first comment.。

Recent Visitors

👥 Today's Visitors -
Loading…
© 2026 WaytoICT | ICP 蜀ICP备2020035321号-2 | Privacy Policy | Disclaimer
Wechat Pay
Alipay
Please use Alipay or WeChat scan to pay